Welcome to our Expert search

Choose from a variety of constructions in the application areas roof, wall and ceiling. Use our Expert search to quickly and flexibly find the right structures for your planning task.

This is how easily our search works:

  1. Set the filters
  2. Select a suitable construction
  3. Check the system layer PDF & properties
  4. Login to myEGGER: Download construction data without restrictions

Our tip: Simply highlight your favorites to stay informed of any updates!

 

 

Technical Support

You have any technical questions or need support concerning our products and their application? Our application engineers are pleased to support you with any queries you have:

 

Filter

Application
4 additional Filters
Fire resistance
16 additional Filters
Insulation material
11 additional Filters
Sound insulation
8 additional Filters
1 to 30 of 96

All constructions

Exterior walls

Construction E1101-01

E1101-01
Construction layer (PDF)
File size 1,0 MB
  • Fire resistance: EI0
  • Fire classification report: ./.
  • Heat insulation: Variable insulation material possible
  • Inner surface wall: OSB visible possible
Exterior walls

Construction E1101-03

E1101-03
Construction layer (PDF)
File size 1,1 MB
  • Fire resistance: F30-B
  • Fire classification report: Fire resistance F30-B according to DIN 4102-4; table 10.7, row 1
  • Heat insulation: Rock wool 30kg/m³
  • Inner surface wall: OSB visible possible
Exterior walls

Construction E1102-03

E1102-03
Construction layer (PDF)
File size 1,5 MB
  • Fire resistance: F30-B
  • Fire classification report: Test report MFPA P-SAC-02/III-752
  • Heat insulation: Cellulose blow-in insulation 50 kg/m³
  • Inner surface wall: OSB visible possible
Exterior walls

Construction E1102-03a

E1102-03a
Construction layer (PDF)
File size 1,3 MB
  • Fire resistance: F30-B
  • Fire classification report: Test report MFPA P-SAC-02/III-752
  • Heat insulation: Cellulose blow-in insulation 50 kg/m³
  • Inner surface wall: inner surface gypsum cardboard ready to paint
Exterior walls

Construction E1102-03b

E1102-03b
Construction layer (PDF)
File size 1,4 MB
  • Fire resistance: F30-B
  • Fire classification report: Test report MFPA P-SAC-02/III-752
  • Heat insulation: Cellulose blow-in insulation 50 kg/m³
  • Inner surface wall: Installation level insulated variable
Exterior walls

Construction E1102-03c

E1102-03c
Construction layer (PDF)
File size 1,3 MB
  • Fire resistance: F30-B
  • Fire classification report: Test report MFPA P-SAC-02/III-752
  • Heat insulation: Cellulose blow-in insulation 50 kg/m³
  • Inner surface wall: Installation level not insulated
Exterior walls

Construction E1103-02

E1103-02
Construction layer (PDF)
File size 1,5 MB
  • Fire resistance: REI30
  • Fire classification report: Classification report HF Austria 2586/2018/20-BB
  • Heat insulation: Variable insulation material possible
  • Inner surface wall: OSB visible possible
Exterior walls

Construction E1103-03

E1103-03
Construction layer (PDF)
File size 1,4 MB
  • Fire resistance: F30-B
  • Fire classification report: Fire resistance F30-B according to DIN 4102-4; table 10.7, row 1
  • Heat insulation: Rock wool 30 kg/m³
  • Inner surface wall: OSB visible possible
Exterior walls

Construction E1104-03

E1104-03
Construction layer (PDF)
File size 1,5 MB
  • Fire resistance: F30-B
  • Fire classification report: Test report MFPA P-SAC-02/III-752
  • Heat insulation: Cellulose blow-in insulation 50 kg/m³
  • Inner surface wall: OSB visible possible
Exterior walls

Construction E1105-03

E1105-03
Construction layer (PDF)
File size 1,4 MB
  • Fire resistance: F30-B
  • Fire classification report: Fire resistance F30-B according to DIN 4102-4
  • Heat insulation: Rock wool 30kg/m³
  • Inner surface wall: inner surface OSB exposed
Exterior walls

Construction E1105-03a

E1105-03a
Construction layer (PDF)
File size 1,1 MB
  • Fire resistance: F30-B
  • Fire classification report: Fire resistance F30-B according to DIN 4102-4
  • Heat insulation: Rock wool 30kg/m³
  • Inner surface wall: inner surface gypsum cardboard ready to paint
Exterior walls

Construction E1105-03b

E1105-03b
Construction layer (PDF)
File size 1,1 MB
  • Fire resistance: F30-B
  • Fire classification report: Fire resistance F30-B according to DIN 4102-4
  • Heat insulation: Rock wool 30kg/m³
  • Inner surface wall: inner surface gypsum cardboard ready to paint
Exterior walls

Construction E1107-02

E1107-02
Construction layer (PDF)
File size 1,5 MB
  • Fire resistance: REI30
  • Fire classification report: Classification report HF Austria 2586/2018/17-BB
  • Heat insulation: Cellulose insulation
Exterior walls

Construction E1107-02a

E1107-02a
Construction layer (PDF)
File size 1,3 MB
  • Fire resistance: REI30
  • Fire classification report: Classification report HF Austria 2586/2018/17-BB
  • Heat insulation: Cellulose insulation
Exterior walls

Construction E1107-02b

E1107-02b
Construction layer (PDF)
File size 1,2 MB
  • Fire resistance: REI30
  • Fire classification report: Classification report HF Austria 2586/2018/17-BB
  • Heat insulation: Cellulose insulation
Exterior walls

Construction E1107-03

E1107-03
Construction layer (PDF)
File size 1,1 MB
  • Fire resistance: F30-B
  • Fire classification report: Fire resistance F30-B according to DIN 4102-4; table 10.7, row 1
  • Heat insulation: Rock wool 30kg/m³
  • Inner surface wall: OSB visible
Exterior walls

Construction E1107-03a

E1107-03a
Construction layer (PDF)
File size 1,1 MB
  • Fire resistance: F30-B
  • Fire classification report: Fire resistance F30-B according to DIN 4102-4; table 10.7, row 1
  • Heat insulation: Rock wool 30kg/m³
  • Inner surface wall: Gypsum board on installation level
Exterior walls

Construction E1107-03b

E1107-03b
Construction layer (PDF)
File size 1,1 MB
  • Fire resistance: F30-B
  • Fire classification report: Fire resistance F30-B according to DIN 4102-4; table 10.7, row 1
  • Heat insulation: Rock wool 30kg/m³
  • Inner surface wall: Gypsum board on installation level
Exterior walls

Construction E1108-02

E1108-02
Construction layer (PDF)
File size 1,3 MB
  • Fire resistance: REI45
  • Fire classification report: Classification report HF Austria 2586/2018/18
  • Heat insulation: Variable insulation material possible
  • Inner surface wall: inner surface gypsum board ready to paint
Exterior walls

Construction E1109-02

E1109-02
Construction layer (PDF)
File size 1,3 MB
  • Fire resistance: REI30
  • Fire classification report: Classification report HF Austria 2586/2018/15
  • Heat insulation: Variable insulation material possible
  • Inner surface wall: inner surface gypsum board ready to paint
Exterior walls

Construction E1110-02

E1110-02
Construction layer (PDF)
File size 1,3 MB
  • Fire resistance: REI60
  • Fire classification report: Classification report HF Austria 2586/2018/16-BB
  • Heat insulation: Variable insulation material possible
Exterior walls

Construction E1111-02

E1111-02
Construction layer (PDF)
File size 1,2 MB
  • Fire resistance: REI90
  • Fire classification report: Classification report HF Austria 2586/2018/12
  • Heat insulation: Glass wool 11 kg/m³
  • Inner surface wall: inner surface gypsum board ready to paint
Exterior walls

Construction E1112-03

E1112-03
Construction layer (PDF)
File size 1,1 MB
  • Fire resistance: F60-B
  • Fire classification report: Fire resistance F30-B according to DIN 4102-4; table 10.8, row 1
  • Heat insulation: Rock wool 100 kg/m³
Exterior walls

Construction E1151-02

E1151-02
Construction layer (PDF)
File size 1,3 MB
  • Fire resistance: REI30
  • Fire classification report: Classification report HF Austria 2586/2018/20-BB
  • Heat insulation: Variable insulation material possible
  • Inner surface wall: Installation level with rock wool
Exterior walls

Construction E1151-02a

E1151-02a
Construction layer (PDF)
File size 1,3 MB
  • Fire resistance: REI30
  • Fire classification report: Classification report HF Austria 2586/2018/20-BB
  • Heat insulation: Variable insulation material possible
  • Inner surface wall: Installation level with insulation
Exterior walls

Construction E1151-02b

E1151-02b
Construction layer (PDF)
File size 1,3 MB
  • Fire resistance: REI30
  • Fire classification report: Classification report HF Austria 2586/2018/20-BB
  • Heat insulation: Variable insulation material possible
  • Inner surface wall: Installation level not insulated
Exterior walls

Construction E1152-03

E1152-03
Construction layer (PDF)
File size 1,2 MB
  • Fire resistance: F30-B
  • Fire classification report: Fire resistance F30-B according to DIN 4102-4; table 10.6, row 1
  • Heat insulation: Rock wool 30kg/m³
Exterior walls

Construction E1152-03a

E1152-03a
Construction layer (PDF)
File size 1,2 MB
  • Fire resistance: F30-B
  • Fire classification report: Fire resistance F30-B according to DIN 4102-4; table 10.6, row 1
  • Heat insulation: Rock wool 30kg/m³
  • Inner surface wall: Installation level not insulated
Exterior walls

Construction E1152-03b

E1152-03b
Construction layer (PDF)
File size 1,2 MB
  • Fire resistance: F30-B
  • Fire classification report: Fire resistance F30-B according to DIN 4102-4; table 10.6, row 1
  • Heat insulation: Rock wool 30kg/m³
  • Inner surface wall: Installation level insulated
Exterior walls

Construction E1157-02

E1157-02
Construction layer (PDF)
File size 1,3 MB
  • Fire resistance: REI45
  • Fire classification report: Classification report HF Austria 2586/2018/18-BB
  • Heat insulation: Rock wool 30kg/m³
  • Inner surface wall: Installation level with rock wool
1 to 30 of 96

Construction


Share the selected construction as a direct link:


Login

In order to access the constructions in DWG and DXF format as well as the relevant certificates, please register as a business customer on myEGGER.

To the login