E1101-01
  • Fire resistance: EI0
  • Fire classification report: ./.
  • Sound classification report: DIN 4109-33: 2016, table 6, row 1
  • Heat insulation: Variable insulation material possible
  • Inner surface wall: OSB visible possible
  • Installation level: possible
  • Wall height: according to statics
  • Minimum wall thickness: 130 mm for sound
  • Installations: according to DIN 4102-4, 10.1.7
  • Additional information: Basic structure
  • Sound insulation R'w: ≤ 37 dB