E1103-03
  • Fire resistance: F30-B
  • Fire classification report: Fire resistance F30-B according to DIN 4102-4; table 10.7, row 1
  • Sound classification report: DIN 4109-33: 2016, table 6, row 1
  • Heat insulation: Rock wool 30 kg/m³
  • Inner surface wall: OSB visible possible
  • Installation level: possible
  • Wall height: according to statics
  • Installations: according to DIN 4102-4, 10.1.7
  • Sound insulation R'w: ≤ 37 dB