E1101-03
  • Fire resistance: F30-B
  • Fire classification report: Fire resistance F30-B according to DIN 4102-4; table 10.7, row 1
  • Sound classification report: DIN 4109-33: 2016, table 6, row 1
  • Heat insulation: Rock wool 30kg/m³
  • Inner surface wall: OSB visible possible
  • Installation level: possible
  • Wall height: according to statics
  • Minimum wall thickness: 130 mm for sound
  • Installations: according to DIN 4102-4, 10.1.7
  • Sound insulation R'w: ≤ 37 dB

Data download

Construction layer (PDF)
File size 1 MB
Drawings in DWG format
File size: 2 MB
Drawings in DXF format
File size: 4 MB
Fire protection certificate

You can find the BIM enabled data for the Exterior walls system family collected as:

IFC File
File size 30 MB
Revit File
File size 18 MB
Egger Revit Material library
File size 9 MB

Construction


Share the selected construction as a direct link:


Variants in the construction

Exterior walls

Construction E1101-03b

E1101-03b
  • Fire resistance: F-30B
  • Fire classification report: DIN 4102-4:2016, Ta. 10.7, Z. 1
  • Heat insulation: Rock wool 30kg/m³