Egger Logo (OTHER)

Welcome to our Expert search

Choose from a variety of constructions in the application areas roof, wall and ceiling. Use our Expert search to quickly and flexibly find the right structures for your planning task.

This is how easily our search works:

  1. Set the filters
  2. Select a suitable construction
  3. Check the system layer PDF & properties
  4. Login to myEGGER: Download construction data without restrictions

Our tip: Simply highlight your favorites to stay informed of any updates!

 

 

Technical Support

You have any technical questions or need support concerning our products and their application? Our application engineers are pleased to support you with any queries you have:

 

Filter

Application
4 additional Filters
Fire resistance
16 additional Filters
Insulation material
11 additional Filters
Sound insulation
8 additional Filters
31 to 60 of 78

All constructions

Partition wall

Construction E1202-02

E1202-02
Construction layer (PDF)
File size 1,3 MB
  • Fire resistance: REI30 / REI90
  • Verwendbarkeitsnachweis Feuer: Klassifizierungsbericht HF Austria 2586/2018/21-BB
  • Application: Building end wall on the inside with gypsum fire board or gypsum fibre board cladding
  • Heat insulation: Variable insulation material possible
Partition wall

Construction E1203-03

E1203-03
Construction layer (PDF)
File size 1,3 MB
  • Fire resistance: F30-B / F90-B
  • Application: Building end wall, OSB on the inside
  • Heat insulation: Rock wool 30 kg/m³
Partition wall

Construction E1215-02a

E1215-02a
Construction layer (PDF)
File size 1,3 MB
  • Fire resistance: REI90
  • Verwendbarkeitsnachweis Feuer: Klassifizierungsbericht HF Austria 2586/2018/10-BB
  • Application: Building partition wall witht gypsum fire board cladding
  • Heat insulation: Glas wool 11 kg/m³
Partition wall

Construction E1301-02

E1301-02
Construction layer (PDF)
File size 1,2 MB
  • Fire resistance: REI60
  • Verwendbarkeitsnachweis Feuer: Klassifizierungsbericht HF Austria 2586/2018/09-BB
  • Application: Load-bearing, room-enclosing partition wall with gypsum fire board or gypsum fibre board cladding
  • Heat insulation: Glas wool 11 kg/m³
Partition wall

Construction E1302-01

E1302-01
Construction layer (PDF)
File size 1,2 MB
  • Fire resistance: EI0
  • Application: Non-load-bearing partition wall with timber framework
  • Heat insulation: Insulation material B2
Partition wall

Construction E1302-01a

E1302-01a
Construction layer (PDF)
File size 1,2 MB
  • Fire resistance: EI0
  • Application: Non-load-bearing partition wall with timber framework
  • Heat insulation: Insulation material B2
Partition wall

Construction E1303-01

E1303-01
Construction layer (PDF)
File size 1,2 MB
  • Fire resistance: EI0
  • Application: Non-load-bearing partition wall with timber framework
  • Heat insulation: Insulation material B2
Partition wall

Construction E1303-02

E1303-02
Construction layer (PDF)
File size 1,4 MB
  • Fire resistance: REI90
  • Verwendbarkeitsnachweis Feuer: Klassifizierungsbericht HF Austria 2586/2018/10 + 17-BB
  • Application: Load-bearing, room-enclosing partition wall with gypsum fire board or gypsum fibre board cladding
  • Heat insulation: Glas wool 11 kg/m³
Partition wall

Construction E1303-02a

E1303-02a
Construction layer (PDF)
File size 1,3 MB
  • Fire resistance: REI90
  • Verwendbarkeitsnachweis Feuer: Klassifizierungsbericht HF Austria 2586/2018/10 + 17-BB
  • Application: Load-bearing, room-enclosing partition wall with gypsum fire board or gypsum fibre board cladding
  • Heat insulation: Glas wool 11 kg/m³
Partition wall

Construction E1306-03

E1306-03
Construction layer (PDF)
File size 1,5 MB
  • Fire resistance: F30-B
  • Fire classification report: abP MFPA P-SAC-02/III-752
  • Application: Load-bearing, room-enclosing partition wall with single-layer cladding
  • Heat insulation: Cellulose insulation
Partition wall

Construction E1306-03a

E1306-03a
Construction layer (PDF)
File size 1,3 MB
  • Fire resistance: F30-B
  • Fire classification report: abP MFPA P-SAC-02/III-752
  • Application: Load-bearing, room-enclosing partition wall with single-layer cladding
  • Heat insulation: Cellulose insulation
Partition wall

Construction E1307-02

E1307-02
Construction layer (PDF)
File size 1,2 MB
  • Fire resistance: REI30
  • Fire classification report: Classification report HF Austria 2586/2018/23-BB
  • Load-bearing, room-enclosing partition wall with gypsum fire board cladding
  • Heat insulation: Variable insulation material possible
Partition wall

Construction E1307-02a

E1307-02a
Construction layer (PDF)
File size 1,3 MB
  • Fire resistance: REI30
  • Fire classification report: Classification report HF Austria 2586/2018/23-BB
  • Load-bearing, room-enclosing partition wall with gypsum fire board cladding
  • Heat insulation: 120 mm variable insulation material possible
Partition wall

Construction E1310-03

E1310-03
Construction layer (PDF)
File size 1,1 MB
  • Fire resistance: F30-B
  • Application: Load-bearing, room-enclosing partition wall with single-layer cladding
  • Heat insulation: Rock wool 30 kg/m³
Partition wall

Construction E1312-03

E1312-03
Construction layer (PDF)
File size 1,2 MB
  • Fire resistance: F60-B
  • Application: Load-bearing, room-enclosing partition wall with Plasterboard cladding
  • Heat insulation: Rock wool 50 kg/m³
Partition wall

Construction E1312-03a

E1312-03a
Construction layer (PDF)
File size 1,2 MB
  • Fire resistance: F60-B
  • Load-bearing, room-enclosing partition wall with gypsum fire board cladding
  • Heat insulation: Rock wool 50 kg/m³
Partition wall

Construction E1314-03

E1314-03
Construction layer (PDF)
File size 1,2 MB
  • Fire resistance: F60-B
  • Application:Load-bearing, not room-enclosing partition wall with Plasterboard cladding
  • Heat insulation: Insulation material B2
Partition wall

Construction E1314-03a

E1314-03a
Construction layer (PDF)
File size 1,2 MB
  • Fire resistance: F60-B
  • Application:Load-bearing, not room-enclosing partition wall with Plasterboard cladding
  • Heat insulation: Insulation material B2
Partition wall

Construction E1315-03

E1315-03
Construction layer (PDF)
File size 1,2 MB
  • Fire resistance: F30-B
  • Application: Load-bearing, not room-enclosing partition wall with single-layer cladding
  • Heat insulation: Insulation material B2
Partition wall

Construction E1315-03a

E1315-03a
Construction layer (PDF)
File size 1,2 MB
  • Fire resistance: F30-B
  • Application: Load-bearing, not room-enclosing partition wall with single-layer cladding
  • Heat insulation: Insulation material B2
Partition wall

Construction E1316-02

E1316-02
Construction layer (PDF)
File size 1,2 MB
  • Fire resistance: REI60
  • Verwendbarkeitsnachweis Feuer: Klassifizierungsbericht HF Austria 2586/2018/09-BB
  • Application: Load-bearing, room-enclosing partition wall with gypsum fire board or gypsum fibre board cladding
  • Heat insulation: Glas wool 11 kg/m³
Partition wall

Construction E1319-03

E1319-03
Construction layer (PDF)
File size 1,1 MB
  • Fire resistance: F90-B
  • Load-bearing, room-enclosing partition wall with gypsum fire board cladding
  • Heat insulation: Rock wool 50kg/m³
Partition wall

Construction E1319-03a

E1319-03a
Construction layer (PDF)
File size 1,1 MB
  • Fire resistance: F90-B
  • Load-bearing, room-enclosing partition wall with gypsum fire board cladding
  • Heat insulation: Rock wool 100kg/m³
Roof

Construction E2103-03

E2103-03
Construction layer (PDF)
File size 1,1 MB
  • Fire resistance: F30-B
  • Fire classification report: Fire resistance F30-B according to DIN 4102-4:2016, table 10.20, row 10
  • Insulation material: Rock wool 30 kg/m³
  • Roof shape: Pitched roof
Roof

Construction E2201-03

E2201-03
Construction layer (PDF)
File size 894,7 kB
  • Fire resistance: F30-B
  • Fire classification report: Fire resistance F30-B according to DIN 4102-4:2016, table 10.25, row 1
  • Insulation material: Rock wool 30 kg/m³
  • Roof shape: Pitched roof
Roof

Construction E2201-03a

E2201-03a
Construction layer (PDF)
File size 768,5 kB
  • Fire resistance: F30-B
  • Fire classification report: Fire resistance F30-B according to DIN 4102-4:2016, table 10.25, row 1
  • Insulation material: Foam plastic
  • Roof shape: Pitched roof
Roof

Construction E2201-03b

E2201-03b
Construction layer (PDF)
File size 893,9 kB
  • Fire resistance: F30-B
  • Fire classification report: Fire resistance F30-B according to DIN 4102-4:2016, table 10.25, row 3
  • Insulation material: Foam plastic
  • Roof shape: Pitched roof
Roof

Construction E2202-03

E2202-03
Construction layer (PDF)
File size 542,8 kB
  • Fire resistance: F30-B
  • Fire classification report: Fire resistance F30-B according to DIN 4102-4:2016, table 10.25, row 2
  • Insulation material: Foam plastic
  • Roof shape: Pitched roof
Roof

Construction E2202-03a

E2202-03a
Construction layer (PDF)
File size 809,1 kB
  • Fire resistance: F30-B
  • Fire classification report: Fire resistance F30-B according to DIN 4102-4:2016, table 10.6, row 3
  • Insulation material: Foam plastic
  • Roof shape: Pitched roof
Roof

Construction E2501-03

E2501-03
Construction layer (PDF)
File size 1,3 MB
  • Fire resistance: F30-B
  • Fire classification report: Fire resistance F30-B according to DIN 4102-4:2016, table 10.19, row 1
  • Insulation material: Insulation material normal flammability
  • Roofing: Flat roof
31 to 60 of 78

Construction


Share the selected construction as a direct link:


Login

In order to access the constructions in DWG and DXF format as well as the relevant certificates, please register as a business customer on myEGGER.

To the login