Ceilings Ceilings

Construction E3501-01

The essentials
Keep on the safe side with our basic constructions.
E3501-01
  • Fire resistance: EI0
  • Fire classification report: none
  • Insulation material: Variable insulation material possible
  • Screed structure: Screed variable to add
  • Screed height: variable
  • Load: acc. to statics
  • Soffit of ceiling: OSB
  • Sound insulation Rw (C,Ctr): ca. 69 dB
  • Sound insulation impact sound Ln,w: ca. 72 dB
  • Remarks: min. 180 mm beam height

Data download

Construction layer (PDF)
File size 1,2 MB
Drawings in DWG format
File size: 2,2 MB
Drawings in DXF format
File size: 3,4 MB
Fire protection certificate

You can find the BIM enabled data for the Ceilings system family collected as:

Revit File
File size 8,0 MB
Egger Revit Material library
File size 9,4 MB

In order to access the constructions in IFC and REVIT format, please register as a business customer on myEGGER.

To the login

Construction


Share the selected construction as a direct link:


Variants in the construction E3501-01

Ceilings

Construction E3501-01a

E3501-01a
Construction layer (PDF)
File size 1,2 MB
  • Fire resistance: EI0
  • Fire classification report: none
  • Insulation material: Variable insulation material possible
  • Screed structure: Dry screed OSB 18 mm + TS MW 15 mm
Ceilings

Construction E3501-01b

E3501-01b
Construction layer (PDF)
File size 1,1 MB
  • Fire resistance: EI0
  • Fire classification report: none
  • Insulation material: Rock wool 30kg/m³
  • Screed height: Zementestrich + TS MW 25mm

Login

In order to access the constructions in DWG and DXF format as well as the relevant certificates, please register as a business customer on myEGGER.

To the login