Partition wall Partition wall

Construction E1312-03a

The rocky
Our constructions insulated with rock wool rock every project together with you.
E1312-03a
  • Fire resistance: F60-B
  • Load-bearing, room-enclosing partition wall with gypsum fire board cladding
  • Heat insulation: Rock wool 50 kg/m³
  • Inner surface wall: 15mm OSB with gypsum fire board
  • Number of layers inside: Two-layer cladding
  • Vertical load: Utilisation 0,2
  • Minimum wall thickness: 135 mm
  • Sound insulation: Rw(c;ctr): 37 (-2,-7) dB

Data download

Construction layer (PDF)
File size 1,2 MB
Drawings in DWG format
File size: 1,4 MB
Drawings in DXF format
File size: 3,4 MB
Fire protection certificate

You can find the BIM enabled data for the Partition wall system family collected as:

Revit File
File size 15,2 MB
Egger Revit Material library
File size 9,4 MB

In order to access the constructions in IFC and REVIT format, please register as a business customer on myEGGER.

To the login

Construction


Share the selected construction as a direct link:


Zugehörige Anschlussdetails für E1312-03a

Rule Details an Rule Details

Regeldetail E-IF02

E-IF02

Anschluss: Innenwand an Decke (sichtbar)

Rule Details an Rule Details

Regeldetail E-IF01

E-IF01

Anschluss: Innenwand an Decke (geschlossen)

Rule Details an Rule Details

Regeldetail E-IR01

E-IR01

Dach: Innenwand an Warmdach 

Variants in the construction E1312-03a

Partition wall

Construction E1312-03

E1312-03
Construction layer (PDF)
File size 1,2 MB
  • Fire resistance: F60-B
  • Application: Load-bearing, room-enclosing partition wall with Plasterboard cladding
  • Heat insulation: Rock wool 50 kg/m³

Login

In order to access the constructions in DWG and DXF format as well as the relevant certificates, please register as a business customer on myEGGER.

To the login