Ceilings Ceilings

Construction E3201-03

The open-hearted
All the way – our constructions with visible beam tier.
E3201-03
  • Fire resistance: F30-B
  • Fire classification report: Fire resistance F30-B according to DIN 4102-4, table 10.16, row 1
  • Thermal insualtion: Exposed beam layer
  • Screed height: Dryscreed
  • Total ceiling height: 408 mm
  • Screed height: 103 mm
  • Ceiling weighting: Betonplatten >140kg/m³, vollflächig verklebt
  • Sound insulation Rw (C,Ctr): > 50 dB
  • Sound insulation impact sound Ln,w: 53 dB

Data download

Construction layer (PDF)
File size 962,2 kB
Drawings in DWG format
File size: 1,5 MB
Drawings in DXF format
File size: 4,3 MB
Fire protection certificate

You can find the BIM enabled data for the Ceilings system family collected as:

Revit File
File size 8,0 MB
Egger Revit Material library
File size 9,4 MB

In order to access the constructions in IFC and REVIT format, please register as a business customer on myEGGER.

To the login

Construction


Share the selected construction as a direct link:


Variants in the construction E3201-03

Ceilings

Construction E3201-03a

E3201-03a
Construction layer (PDF)
File size 972,7 kB
  • Fire resistance: F30-B
  • Fire classification report: Fire resistance F30-B according to DIN 4102-4, table 10.16, row 1
  • Thermal insualtion: Exposed beam layer
  • Screed height: Dryscreed

Login

In order to access the constructions in DWG and DXF format as well as the relevant certificates, please register as a business customer on myEGGER.

To the login