Ceilings Ceilings

Construction E3102-02a

The open-hearted
All the way – our constructions with visible beam tier.
E3102-02a
  • Fire resistance: REI45
  • Fire classification report: Classification report HF Austria 2586/2018/32-BB
  • Thermal insualtion: Exposed beam layer
  • Screed height: Dryscreed
  • Total ceiling height: 475 mm
  • Screed height: 85 mm
  • Load: 5,3 kN/m³
  • Sound insulation Rw (C,Ctr): 65 dB
  • Sound insulation impact sound Ln,w: 54(0) dB

Data download

Construction layer (PDF)
File size 1,2 MB
Drawings in DWG format
File size: 1,1 MB
Drawings in DXF format
File size: 3,6 MB
Fire protection certificate

You can find the BIM enabled data for the Ceilings system family collected as:

Revit File
File size 8,0 MB
Egger Revit Material library
File size 9,4 MB

In order to access the constructions in IFC and REVIT format, please register as a business customer on myEGGER.

To the login

Construction


Share the selected construction as a direct link:


Variants in the construction E3102-02a

Ceilings

Construction E3102-02

E3102-02
Construction layer (PDF)
File size 1,2 MB
  • Fire resistance: REI45
  • Fire classification report: Classification report HF Austria 2586/2018/32-BB
  • Thermal insualtion: Exposed beam layer
  • Screed height: Dryscreed

Login

In order to access the constructions in DWG and DXF format as well as the relevant certificates, please register as a business customer on myEGGER.

To the login